1. Solarbank E1600 System
1.1 WorkingPrinciples
1.1.1 How does Solarbank E1600 work?
  Solarbank E1600 is connected between the photovoltaic panels and microinverter. When sunlight is sufficient and the photovoltaic panels are supplying power, you can control the output power of the microinverter by adjusting the charging power of Solarbank E1600 so as to supply power to the household. When sunlight is insufficient or the energy generated by photovoltaic panels is far lower than the household power demand, the photovoltaic power supply is switched to the battery power supply. The photovoltaic panels and batteries cannot power the household at the same time.
  The allocation logic is as follows: You can configure power requirements for different time periods in the "Anker app" according to your power consumption habits. In accordance with the difference between the generated photovoltaic power and your power consumption demand, the power supply source can be divided into three cases:
  • When sunlight is sufficient, photovoltaic power is used to supply power to the household according to the set power, and the excess power is charged and stored in the battery. When the battery is fully charged or is not charging due to low temperature, photovoltaic power will be fully output through the microinverter to supply power to the household.
  • When sunlight is insufficient, if the conditions for switching photovoltaic discharge to battery discharge are met, the photovoltaic power supply will be switched to the battery power supply, and the battery will power the household according to the set power. If the conditions are not met, the photovoltaic power supply continues. In this condition, the output power of the microinverter may not meet the household power demand. There are two conditions for switching the photovoltaic power supply to the battery power supply: The first condition is that, when the photovoltaic input power is less than 20 W (with a duration of more than 10 minutes), or when the photovoltaic input power is less than 100 W and the set "Family Load" power is 100 W greater than the actual photovoltaic input power (with a duration of more than 10 minutes), the switchover occurs.
  • The other condition is that, when sunlight is insufficient and photovoltaic panels are not generating electricity, the battery will power the household according to the desired power.
For example:
  • If the power consumption demand at noon is 100 W and the generated photovoltaic power is 600 W, since the generated photovoltaic power (600 W) is much greater than the power consumption demand (100 W), Solarbank E1600 will simultaneously supply 100 W of power to the household through the microinverter and store 500 W in the battery.
  • If the power consumption demand in the evening is 600 W and the generated photovoltaic power is 50 W, since the generated photovoltaic power (50 W) is far less than the power consumption demand (600 W), the battery will supply 600 W of power to the household.
  • If the power consumption demand in the evening is 600 W and the generated photovoltaic power is 10 W, since the generated photovoltaic power is less than 20 W, the battery will supply 600 W of power to the household.
  • If the power consumption demand in the morning is 150 W and the generated photovoltaic power is 80 W, in order to make better use of the generated photovoltaic power, Solarbank E1600 outputs 80 W through the microinverter to the grid, and the battery does not supply any power.

1.2 Abnormal Family Load
1.2.1 Why does the microinverter still have power output even after I have set the power in the "Family Load Setting" to 0 W in the Anker app?
  You can control the startup and shutdown of the MI80 microinverter for a power output of 0 only when Solarbank E1600 works with the MI80 microinverter and the network connection between them is normal.
  You cannot control the startup and shutdown of the microinverter when Solarbank E1600 is working with a third-party microinverter. As long as the photovoltaic panel is generating electricity, the microinverter will start and run at the minimum stable power (about 150 W), and therefore the output power will not be 0 W.   You can achieve a power output of 0 W only when the battery is discharged.

1.2.2 Why is the output power of the microinverter greater than the power set in the "Family Load Setting"?
  The following cases are both normal situations.
  For example:
  • When the Solarbank E1600 battery is being charged: the microinverter operates stably at the maximum power before it starts to adjust the charging power of the battery. Therefore, during the startup process of the microinverter, the output power will transiently exceed the power set in the "Family Load Setting".
  • When the Solarbank E1600 battery is almost full: in order to protect the battery, it is charged at a low power. In this situation, the charging power decreases and the output power of the microinverter increases and exceeds the power set in the "Family Load Setting".

1.3 Power of the Microinverter Fluctuating
1.3.1 Why is the output power of the microinverter fluctuating greatly?
  The microinverter has poor compatibility, and its output is prone to instability in the following 2 conditions. Therefore, we recommend that you use the MI80 microinverter, which has better compatibility, for improved stability.
  • When the light intensity changes and the output power of the microinverter approaches the lower limit for stable microinverter operation (about 150 W), the output becomes unstable.
  • When the light intensity is stable and the set power in the "Family Load Setting" approaches the lower limit for stable microinverter operation, the output becomes unstable (note that the minimum power for the stable operation of certain third-party microinverters is much greater than 150 W, such as for Deye microinverters.)

1.4 Abnormal Charging in Normal Conditions
1.4.1 Why is the charging power of the battery only 35 W when the light intensity is high?
  Before the microinverter operates properly, the charging power of the battery is only 35 W, Including the following scenarios:
  • Before the microinverter is successfully started, the battery is charged at a power of about 35 W to reserve sufficient power for the microinverter to be started. After the microinverter operates stably, the charging power of the battery will increase. (Some third-party microinverters take up to 7 minutes to start up, and therefore please wait patiently for the startup to complete.)
  • If you are using the MI80 microinverter, the battery will be charged at a power of about 35 W when the MI80 microinverter fails to start. In this situation, please check that the Wi-Fi connection status of Solarbank E1600 or the MI80 microinverter is normal.
  • When a municipal power outage occurs or the AC cable of the microinverter is disconnected.

1.4.2 Why does the generated power of the photovoltaic panel and the charging power of the battery decrease when the light intensity is high?
  If you have set the power in the "Family Load Setting" to 0 W, when the battery is charged to 90%, the charging power will decrease to protect the battery, in which case the photovoltaic power will also decrease.
  If your Solarbank E1600 is working with the MI80 microinverter, we recommend that you set the "Priority Charging Percentage" to 90% so that the microinverter will run at a minimum power output of 100 W, and the remaining power of the photovoltaic panel will be used to charge the battery.
  If your Solarbank E1600 is used with a non-MI80 microinverter, you can enable the "Output to Family" feature in Energy Deploy. In this way, photovoltaics can power household loads.

1.4.3 Why can’t I charge the battery even when the remaining capacity of the battery is lower than 5%?
  This issue can occur in the following conditions:
  • The version of the app or Solarbank E1600 is relatively old: If this is the case, upgrade the app to the latest version, and then upgrade the Solarbank firmware to the latest version.
  • The photovoltaic panel is operating improperly: Only connect Solarbank E1600 to the photovoltaic panel and not to the microinverter. Then, press and hold both buttons on Solarbank E1600 for 15 seconds to restart it until the indicator flashes.
screenshot-20240715-174247.png
  Now, if the photovoltaic panel is operating properly, it will be slowly charged at a power of 35 W. If there are any abnormalities, check whether the cable of the photovoltaic panel is damaged and whether the wires connected to Solarbank E1600 are the correct ones and are secure.
 
1.5 Abnormal Discharging
1.5.1 Why doesn’t the battery discharge and why can’t the output power of the microinverter meet the power demand when the light intensity is low?
  The photovoltaic panel and battery cannot supply power at the same time. Instead, the photovoltaic panel swaps to battery discharge only in the following 2 conditions:
  • The photovoltaic input remains less than 20 W for more than 10 minutes.
  • The photovoltaic input power remains less than 100 W and the power set in the "Family Load Setting" remains 100-W higher than the actual photovoltaic input power for more than 10 minutes.
  If neither of these conditions occurs and battery discharge is urgently required, we recommend that you remove the cable between the photovoltaic panel and Solarbank E1600.

1.6 Firmware Update Failed
1.6.1 What should I do if the upgrade of the Solarbank firmware fails?
  If the Anker APP reports that the upgrade failed, the device will still try to complete the remaining steps. In this situation, please wait about 10 minutes and verify the device version.
  If the firmware upgrade is still not completed, it is most likely due to a Wi-Fi connection issue. Check the Wi-Fi connection status of Solarbank and MI80 (if there is any), ensure that the Wi-Fi network has been configured for your device and is on, and check that the device is online. If the network connectivity is poor, you can temporarily use your cell phone as a hotspot instead of the Wi-Fi network to do the upgrade.

1.7 WiFi Connection Related
1.7.1 What should I do if Solarbank E1600 cannot be connected to the Anker app or is frequently disconnected?
  You can temporarily use your cell phone as a hotspot instead of the Wi-Fi network. If the Solarbank E1600 connection is stable, the problem was caused by the Wi-Fi connection. In this situation, you can try to resolve the problem by completing the following steps:
  • Check that the router is communicating with Solarbank E1600 at 2.4 GHz, because Solarbank E1600 does not support Wi-Fi communications at 5 GHz.
  • Relocate the device to a position that is within 10 meters of the router. Also, ensure that few obstacles and walls (if possible) exist between them to ensure that there is a strong Wi-Fi signal. Alternatively, add more repeaters to enhance the signal.
  • Check whether the number of devices connected to the Wi-Fi network has reached the upper limit. If it has, disconnect some devices.
  • Check whether the "IOT Status LED" is flashing green. When it flashes green, the connection is being reestablished. In this situation, you can use your cell phone to establish a Bluetooth connection with Solarbank E1600, and then reconfigure the Wi-Fi connection.
  • Upgrade both the app and firmware to their latest versions.
 
1.8 Standby
1.8.1 How should I get Solarbank to start operating when it is in the Standby state?
  The Standby state means that the battery is not being charged or discharged, and it does not mean that Solarbank is not operating. When the battery state changes and charging or discharging begins, the Standby state will disappear automatically.
In the following conditions, you may find that Solarbank is displayed as being in Standby in the Anker app:
  • The conditions for the photovoltaic panel to swap to battery discharge are as follows:
  • The household load has a demand for power, and the power set in the "Family Load Setting" is not 0 W in the Anker app.
  • The light intensity is high, and the system has determined that the battery can be charged, but the battery is already fully charged; or, the temperature is around 0 °C and the battery cannot be charged.
  • The light intensity is low, but the photovoltaic panel and battery cannot supply power at the same time, and the conditions for the photovoltaic panel to swap to battery discharge have not been met. As a result, the battery does not discharge, and the system displays Standby.
  • No light is available, and the power in the "Family Load Setting" is set to 0 W. Therefore, the battery does not discharge and the system displays Standby.
  Note:
  The conditions for the photovoltaic panel to swap to battery discharge are as follows:
The household load has a demand for power, and the power set in the "Family Load Setting" is not 0 W in the Anker app.
  • The photovoltaic input remains less than 20 W for more than 10 minutes.
  • The photovoltaic input power remains less than 100 W and the power set in the "Family Load Setting" remains 100-W higher than the actual photovoltaic input power for more than 10 minutes.

1.9 System Compatibility
1.9.1 Can my photovoltaic panels work with Solarbank E1600?
  Both input ports of Solarbank can be connected to photovoltaic panels with an operating voltage of 11 V to 60 V.
  However, the total Isc of the panels that can be connected to both input ports of Solarbank must not exceed 30 A, otherwise, with sufficient sunlight, the panels may shut down due to overcurrent protection.
Given that Solarbank has only one MPPT, we recommend that you connect panels of the same model to the input ports of Solarbank and place the panels at similar angles and toward similar directions.

1.9.2 Can my microinverters work with Solarbank E1600?
  Solarbank E1600 is compatible with microinverters with a voltage between 11 V and 60 V. In addition, MI80 microinverters possess better compatibility and the best stability. APsystems and Hoymiles microinverters also feature sound stability, and other microinverters may experience fluctuations in household load power due to compatibility issues.

1.9.3 Can my microinverter work with two Solarbank E1600 units?
  Currently, we only support connecting two Solarbank E1600 units to an MI80 microinverter in order to have them work together. Other microinverters are not supported yet.
  Note the following when wiring: Always connect two Solarbank E1600 units to both input ports of the same MI80 microinverter, but do not connect the output port of one Solarbank unit to the input port of the other Solarbank unit.
  After turning on both Solarbank units, follow the instructions in the Anker app to add the first Solarbank unit on the "Device" screen, and then bind it to the MI80 microinverter to finish establishing the Homessytem. Next, on the "Device" screen, add the other Solarbank unit and bind it to the same microinverter. Finally, go to the "Homesystem" page of the first Solarbank unit, tap the plus sign ("+") in the upper right corner, and select "Add a device" to add the other Solarbank unit to the Homesystem.
The Homesystem controls the power in terms of the overall system, where you should note that:
  • You can only set the total output power of the two Solarbank E1600 units to 0 W, but cannot set one of them to 0 W and not set the other to 0 W.
  • When the total output power is not 0 W, by default, both Solarbank E1600 units distribute the power equally according to the set power. You can also set the output power of each Solarbank E1600 unit in "Advanced settings" as needed, and their output power values can be different.
  • When the Wi-Fi connections between both Solarbank E1600 units and the MI80 microinverter are normal, if one of the units has reached the minimum power and cannot supply power, the other unit will continue to supply power to the household.

1.9.4 Can Solarbank E1600 work with the Smart Meter or smart sockets such as Shelly?
  No, Solarbank E1600 does not support being used with any other smart devices (such as the Shelly smart socket or Solarbank2 smart meter). Instead, you can only manually set up a household power consumption plan. Solarbank 2 E1600 Pro can be used with the Anker SOLIX Smart Meter to intelligently manage household power consumption.

1.9.5 Can I incorporate the Solarbank E1600 system's data (energy production and power consumption) into my household software IoBroker/Home Assistant?
  Sorry, it only supports managing the data in the Anker app and does not support integrating into third-party systems.

1.10 Indicator of Solarbank E1600 Flashes Red
1.10.1 What should I do when the indicator of Solarbank E1600 flashes red?
  1. If the indicator flashes red, wait for 30 seconds to see whether the fault will be corrected automatically. If it is corrected, then no further action is required.
  2. If it is not corrected, then press the power button once to manually correct the fault.
  3. If this does not correct the fault, remove the input and output cables of Solarbank E1600 and turn it off and then on again. Next, troubleshoot based on the following possible conditions:
  • If the indicator still flashes red after the restart, the fault may stem from Solarbank E1600.
  • If the indicator no longer flashes red after the restart, the fault may stem from the photovoltaic panels or the microinverter. To determine the exact cause, connect Solarbank E1600 to only the microinverter or only the photovoltaic panels, and check if the indicator still flashes red to identify whether the fault is coming from the photovoltaic panels or the microinverter.
2. 0W Switch
2.1 Disconnected
2.1.1 Why does the 0W switch grayed out and show "Connecting" in the Anker app?
  Solarbank E1600 requires the 0W switch to achieve 0 W output only when working with non-MI80 microinverters. In other words, MI80 microinverters do not require the 0W switch.
When photovoltaic power generation is normal, the 0W switch is also working properly. In this condition, if the 0W switch has established a Bluetooth connection with Solarbank E1600, the indicator of the 0W switch is solid white. On the Solarbank page of the Anker app, the 0W switch is black (online).
The 0W switch is grayed out (offline) under two conditions:
  • If the Bluetooth connection between the 0W switch and Solarbank E1600 is normal initially but disconnected later, the indicator of the 0W switch flashes white once, indicating that it is waiting for Bluetooth connection to be repaired. In this condition, the state of the 0W switch is grayed out (offline) on the Solarbank page of the Anker app.
  • When there is no sunlight, the "Family Load Setting" is set to 0. In this condition, the 0W switch is not powered and its indicator is off. On the Solarbank page of the Anker app, the 0W switch is grayed out (offline), which is normal.

3. MI80 Microinverter
3.1 Specification
3.1.1 The maximum output power allowed for balcony photovoltaics in Germany has been increased to 800 W. Then, does my MI80 microinverter support 800 W of power?
  If the Wi-Fi connection of your MI80 microinverter is working properly, the MI80 microinverter should have been automatically upgraded to support 800 W. You can check the maximum output power in the Anker app by completing the following steps:
  • Tap "Device" > "MI80 Microinverter".
  • Tap the Setting icon in the upper right corner.
  • Check the "Maximum Output Power". If the value is 800 W, it means that the maximum output power of MI80 has been upgraded to 800 W. If the value remains 600 W, please provide us with your "SN", and we will upgrade MI80 for you.